If you live in an area that requires a shed roof rafter to support a heavy load then an spf rafter can only span 7.
How much will a 2x4 roof joist support.
However it is highly advisable not to push the 2x4 material up to its limit.
How much weight can a 2 4 support vertically.
So if your ceiling is unfinished you have some excess carrying.
Joist span tables use these tables to determine lengths sizes and spacing of ceiling joists.
You are correct in that a 1x would not provide much support for your roof s ridge line.
Such calculations would be valid if for example the load is quadratic.
Would 2x4s be adequate ceiling joists for ceilings with drywall and insulation.
While the heavy load span specs for a 2 4 rafter are much less than a light load they would allow you to have a shed width of over 14 with a gable roof.
Each ceiling joist is one 12 foot 2x4 turned on end and total answered by a verified structural engineer.
Also available for the android os.
If the bottom chord of a roof truss functions as a floor joist such as in an attic room it carries a live load that also varies by use but a typical live floor load for a residential space is about 40 pounds per square foot.
That seems like it would support a lot of dead load.
But if you ask engineers what they do in their own garages you ll get a different answer.
If this is the case with your structure use the floor joist table to determine maximum joist length load.
Span calculator for wood joists and rafters also available for the android os.
That a 4x8 sheet of 3 4 plywood with 2x6 joist on the edge and 2x4 joist in the middle can support.
How much weight can a 2x4 ceiling 16 on center hold.
An syp rafter can span 8.
Assuming the fb of hemfir is maxxed at 1275 psi and i came up with 12 737 psf.
However if there is no strong wind measure 2 4 at least 8 feet can carry at least 1000 pounds vertically.
Here you can work on the assumption that there is no wind or the wind impact effect is not too strong.
They re designed to support your roof not your junk.
If there is no strong wind a 2x4 measuring at least 8 feet can support at least 1 000 pounds vertically.
The horizontal bottom chords of most garage trusses are designed to carry the weight of drywall and insulation.
But i doubt this was the intention.
The fact that your ceiling joists span 15 feet and are only 2x4s and are holding up plaster and lath it makes more sense that the 1xs were trying to support the ceiling joists below.
Such calculations would hold if for instance the load is square.
Ceiling joists of the first floor of a two story structure often serve as floor joists for the second floor.